1
← Environmental Law Center← Centro de Derecho Ambiental
Decreto 38928 · 14/11/2014
OutcomeResultado
SummaryResumen
This regulation, under Law 8839 on Integrated Waste Management, sets the physical and sanitary requirements for sanitary landfills in Costa Rica, covering siting, design, construction, operation, maintenance, and closure. Landfills are classified as manual or mechanized based on daily waste tonnage (threshold: 40 tons). It details procedures with the Ministry of Health: location permit, construction plan review, and sanitary operation permit, also requiring SETENA environmental feasibility and municipal land-use compatibility. Technical specifications include cell waterproofing, leachate and gas management, and groundwater monitoring. It prohibits scavengers in active cells, waste burning, and creation of new open dumps. Closure and conversion of existing dumps are also regulated. The goal is public health and environmental protection, preventing contamination of soil, water, and air.Este reglamento, derivado de la Ley 8839 de Gestión Integral de Residuos, establece los requisitos y condiciones físicas y sanitarias que deben cumplir los rellenos sanitarios en Costa Rica, incluyendo su ubicación, diseño, construcción, operación, mantenimiento y cierre. Clasifica los rellenos en manuales y mecanizados según el tonelaje diario de residuos (umbral de 40 toneladas). Detalla trámites ante el Ministerio de Salud: permiso de ubicación, revisión de planos constructivos y permiso sanitario de funcionamiento, exigiendo además viabilidad ambiental de SETENA y uso conforme del suelo municipal. Fija especificaciones técnicas como impermeabilización de celdas, manejo de lixiviados, gases y monitoreo de aguas subterráneas. Prohíbe la presencia de segregadores en celdas activas, la quema de residuos, y la creación de nuevos vertederos. Las obras de cierre y reconversión de vertederos existentes también se regulan. El objetivo es proteger la salud pública y el ambiente, previniendo la contaminación de suelos, agua y aire.
Key excerptExtracto clave
Article 1.—All sanitary landfills, conversion of open dumps to sanitary landfills, and dump closure works located in the national territory fall within the scope of application of this regulation. Article 2.—OBJECTIVE: This Regulation seeks to establish the physical and sanitary requirements and conditions that landfills must meet in their location, design, construction, operation, and maintenance, as well as post-closure care. Additionally, the requirements and conditions for dump closure works and conversion to a sanitary landfill. The foregoing, with the purpose of protecting public health and the environment. Article 4.—For purposes of this regulation, sanitary landfills are classified according to their mode of operation into two types: a) Manual sanitary landfill. b) Mechanized sanitary landfill.Artículo 1°- Quedan dentro del ámbito de aplicación de este reglamento todos los rellenos sanitarios, reconversión de vertederos a rellenos sanitarios y obras de cierre de vertederos ubicados en el territorio nacional. Artículo 2º- OBJETIVO: El presente Reglamento busca establecer los requisitos y condiciones físicas y sanitarias que deben cumplir los Rellenos tanto en su ubicación, diseño, construcción, operación y mantenimiento; así como al mantenimiento posterior a la vida útil. Además, los requerimientos y condiciones para obras de cierre de vertedero y la reconversión a relleno sanitario. Lo anterior, con la finalidad de proteger la salud pública y el ambiente. Artículo 4°- Para los efectos de este reglamento, los rellenos sanitarios se clasifican según su forma de operación, en dos tipos: a) Relleno sanitario manual. b) Relleno sanitario mecanizado.
Pull quotesCitas destacadas
"La incorrecta disposición final de los residuos sólidos en el país, es un serio problema que atenta severamente contra la salud pública, la vida y un ambiente sano y ecológicamente equilibrado."
"The improper final disposal of solid waste in the country is a serious problem that severely threatens public health, life, and a healthy and ecologically balanced environment."
Considerando 1°
"La incorrecta disposición final de los residuos sólidos en el país, es un serio problema que atenta severamente contra la salud pública, la vida y un ambiente sano y ecológicamente equilibrado."
Considerando 1°
"Los mayores esfuerzos deben acentuarse en los escalones previos de evitar, reducir, reutilizar y valorizar, de tal manera que sea la mínima fracción de residuos la que deba ser tratada y dispuesta finalmente en un relleno sanitario."
"Greater efforts must be focused on the upstream steps of avoiding, reducing, reusing, and recovering, so that the minimum fraction of waste must be treated and finally disposed of in a sanitary landfill."
Considerando 6°
"Los mayores esfuerzos deben acentuarse en los escalones previos de evitar, reducir, reutilizar y valorizar, de tal manera que sea la mínima fracción de residuos la que deba ser tratada y dispuesta finalmente en un relleno sanitario."
Considerando 6°
"Se prohíbe la presencia de personas dedicadas a la recuperación de residuos de cualquier tipo, sean estos valorizables o no, en la celda en operación."
"The presence of persons engaged in the recovery of waste of any type, whether recoverable or not, in the operating cell is prohibited."
Artículo 45
"Se prohíbe la presencia de personas dedicadas a la recuperación de residuos de cualquier tipo, sean estos valorizables o no, en la celda en operación."
Artículo 45
Full documentDocumento completo
the entire text - Complete Text of Regulation 38928 Regulation on Sanitary Landfills Complete Text of record: 16A7E8 Nº 38928-S (This executive decree was repealed by Article 46 of the Regulation on environmental parks for the separation, treatment, utilization and final disposal of solid waste, approved by executive decree N° 44421 of March 4, 2024) THE PRESIDENT OF THE REPUBLIC AND THE MINISTER OF HEALTH, In exercise of the powers conferred by Articles 50 and 140, subsections 3) and 18) of the Political Constitution; Article 28), paragraph 2, subsection b) of Law Nº 6227 of May 2, 1978 "General Law of Public Administration", Articles 4 and 5 of Law Nº 8220 of March 4, 2002 "Law for the Protection of Citizens from the Excess of Administrative Requirements and Procedures", its amendment and regulation, and Articles 4, 7 and 45 of Law Nº 8839 of June 24, 2010 "Law for Integrated Waste Management".
THEY DECREE The following, REGULATION ON SANITARY LANDFILLS
General Provisions
Whereas:
Therefore,
CHAPTER I
Furthermore, the requirements and conditions for open-air dump closure works and reconversion to a sanitary landfill. The foregoing, with the purpose of protecting public health and the environment.
Procedures and requirements for mechanized and manual sanitary landfills
CHAPTER II
In the event of an expansion of the sanitary landfill beyond the property (finca) approved in the location permit, the respective location permit and the plan review procedure must be processed again.
In justified cases, the deadline may be extended upon prior notification to the interested party, but said extension may not exceed 15 calendar days. Once granted, the permit shall be valid for 2 years, a period that shall be computed starting from the date of its issuance.
Along with the construction plans, the design report (memoria de diseño) and the operation and maintenance manual must be attached.
a. The construction plans must contain the following:
1. Initial and final topographic survey.
2. Delimitation of setbacks and easements (servidumbres) of any type.
3. Access roads, internal streets, perimeter fence, with their construction details.
4. Location of the waste disposal cells (celdas) including the following construction details:
4.1 Transverse and longitudinal cross-sections.
4.2 Thicknesses of waste and cover.
4.3 Bottom liners.
4.4 Slopes with the percentage of incline.
4.5 Final cover thickness.
5. Location of the cover material storage area.
6. Leachate (lixiviados) collection, conveyance, and treatment system, including reuse and recirculation if used, with their construction details. The leachate treatment system must comply with the requirements of Executive Decree Nº 31545-S-MINAE "Regulation for the Approval and Operation of Wastewater Treatment Systems", published in the Official Journal "La Gaceta" on December 22, 2003.
7. Gas collection, conveyance, and treatment system, with its construction details.
8. Peripheral and internal collection, conveyance, and disposal system for stormwater, with its construction details.
9. Site plan detail of the equipotential lines and the groundwater flow lines; in reference to the location and construction detail of the groundwater monitoring wells.
10. Potable water and electrical distribution system for the entire project.
11. Buildings: offices, warehouses, workshops, weighing station, dining areas, sanitary facilities, showers, locker rooms, surveillance booths, collection truck and operational equipment washing area with all their construction details.
12. Final configuration and design of the sanitary landfill.
b. The design report (memoria de diseño) of a sanitary landfill must contain the following:
1. Estimation of the design population.
2. Estimation of waste generation.
3. Estimation of volumetric capacity.
4. Estimation of the landfill's useful life.
5. Estimation of gas production and design of the collection, treatment, or utilization system.
6. Estimation of leachate (lixiviados) production, and design of the collection and treatment system.
7. Estimation of the amount of cover material needed, and its availability on the property or from other sources.
8. Design of the dimensions of the cells (celdas), including their slopes.
9. Estimation of stormwater volume, and design of the collection, conveyance, and disposal system.
c. The operation and maintenance manual for a sanitary landfill must contain the following:
1. Description of the daily operation shift including work hours and days of the week worked.
2. Characterization of the profile of the personnel necessary to carry out the different activities and procedures described in the manual.
3. Progress schedule relative to its useful life.
4. Description of the equipment and tools necessary for operation of the landfill.
5. Detailed description of the operation for the disposal of waste and its cover, both during the dry and rainy seasons.
6. Odor mitigation and control measures.
7. Bird and vector control measures.
8. Measures for the mitigation of particulate matter emissions.
9. Enumeration of the most common difficulties, each accompanied by the respective solution.
10. Annual plan of activities for the maintenance of the entire project including the internal routes of the sanitary landfill.
Location of the Sanitary Landfill
CHAPTER III
If the drawdown cone cannot be determined, the distance to the well shall be 500 meters.
Technical Specifications
CHAPTER IV
Likewise, they must be free of perforations and surface imperfections, possess characteristics that do not allow the passage of leachate (lixiviados), and their joints must not allow the passage of liquids. Over the base waterproofed with the geomembrane, a high-density polyethylene geonet (geored) with incorporated geotextile shall be placed to facilitate the drainage of leachate towards the collection pipes.
a. Ability to isolate the waste from the surrounding environment, control the proliferation of sanitary vectors, biogas emanations, and unpleasant odors, the risks of fire, and the entry of rainwater into its interior.
b. Non-combustible.
c. Resistant to erosion and wind drag.
d. Not contain hazardous substances or materials nor be capable of releasing contaminants into the environment.
e. Resistant to surface runoff.
Furthermore, every mechanized sanitary landfill must have the following facilities: offices, warehouses, workshops, weighing station, dining areas, sanitary facilities, showers, locker rooms, surveillance booths, and a washing area for collection trucks and operational equipment.
Manual sanitary landfills shall have the following facilities: warehouses, weighing station, sanitary facilities, showers, locker rooms, surveillance booths.
Operation and Maintenance
CHAPTER V
Said replacement machinery must be available for operation within a period not exceeding 24 hours.
When it is necessary to establish vertical continuity between cells (celdas), this may be carried out by jointly constructing drainage ducts with the cell.
Likewise, within 24 hours of the event occurring, a report must be submitted for the knowledge and information of the corresponding Health Governing Area Directorate (Dirección de Área Rectora de Salud), which must contain the following:
If, due to a contingency or for any other reason, the use of an area or sector of a sanitary landfill becomes impossible or risky, it may not be used until the administrator of the sanitary landfill presents to the Health Governing Area Directorate a project indicating the corrective and repair measures required to be implemented for its rehabilitation, prepared by a professional in the field of civil or sanitary engineering. The Health Governing Area Directorate must verify the implementation of the proposed actions.
Post-Useful Life Maintenance
CHAPTER VI
The manual must contain the following aspects:
If there is a displacement or settlement that presents a potential risk, the corresponding corrective measures must be implemented.
State Oversight
CHAPTER VII
The parameters for the monitoring wells and the receiving body shall be those indicated in Article 38, subsection d) of this regulation. Sampling of the receiving body must be carried out at one site upstream and another site downstream of the sanitary landfill, at a distance of at least 25 m from the boundary of the sanitary landfill and measured along the river channel.
The operational reports shall include the following information, with the exception of landfill closure works, which shall only include subsections c), d), and e) of this article:
a. Daily and monthly average of incoming waste by type, in tons.
b. Vehicle reception log, with the following information:
i. Corresponding month.
ii. Origin of the waste: Municipal, manager, generator.
iii. Identification of the waste origin: indicates the manager's registration code, the municipality, or the generator's name.
iv. Weight (in tons).
v. Type of waste (ordinary, hazardous, special handling).
c. Progress of the landfill fill or closure works.
d. Updated remaining useful life.
e. Laboratory analyses, conducted quarterly for mechanized landfills and landfill closure works, and semi-annually for manual landfills, of the monitoring wells and of the receiving body for the effluent from the leachate treatment system.
This analysis shall include the following parameters:
| No. | Parameter |
|---|---|
| 1. | Chemical Oxygen Demand (COD) |
| 2. | Hydrogen Potential (pH) |
| 3. | Total Solids (TS) |
| 4. | Total Chromium (Cr) |
| 5. | Lead (Pb) |
| 6. | Mercury (Hg) |
| 7. | Nickel (Ni) |
| 8. | Electrical Conductivity |
| 9. | Cadmium (Cd) |
| 10. | Chlorides |
| 11. | Nitrate (NO3) |
| 12. | Nitrites (NO2) |
| 13. | Total Organic Carbon |
The results of the sampling analyses must be compared with the baseline values obtained at the beginning of the sanitary landfill operation, as indicated in Article 37 of this regulation.
f. Report of any incident that occurred during the landfill operation and the corresponding corrective actions.
(Thus amended by Article 60 of the Regulation for the digital processing of registrations and authorizations of the Ministry of Health in waste management on the SINIGIR platform, approved via Executive Decree No. 41525 of December 4, 2018)
Landfill Closure Works and Conversion to Sanitary Landfill
CHAPTER VIII
The leachate treatment system must comply with the provisions of the Regulation for the approval and operation of wastewater treatment systems.
Additionally, a design report containing the following:
And an operation and maintenance manual containing:
It must also comply with the technical requirements stipulated in Article 20 of this regulation, with the exception of subsections a, b, c, k, and m.
Prohibitions
CHAPTER IX
Non-compliance with this provision will result in the operator of the Sanitary Landfill receiving a sanitary order issued to the administrator of the Landfill to proceed with the eviction of the individuals from the property; otherwise, proceedings will lead to the suspension of the Sanitary Operating Permit for the establishment.
Once this period has elapsed, if any type of building is intended to be built, geotechnical studies must be conducted to verify the stability of the ground, and the non-existence of gases and leachate must also be demonstrated. In the event of non-compliance with the provisions of this article, the Ministry of Health shall issue a sanitary order requesting the demolition of the building in accordance with the provisions of Articles 355 and 356 of the General Health Law (Ley General de Salud).
Likewise, the final disposal of waste of any kind in protection areas, wetlands, natural or forest reserves and similar areas, recreation areas and parks, rivers, streams, canals, and in general any body of water.
The burning of waste or any other type of material within the sanitary landfill is prohibited. If these practices are incurred, the offender shall be subject to the sanction established in Article 49 of Law No. 8839 of July 13, 2010, "Law for Integrated Waste Management" (Ley Para La Gestión Integral De Residuos).
REPEAL
CHAPTER X
27378-S of October 9, 1998, published in La Gaceta No. 206 of October 23, 1998, "Reglamento sobre Rellenos Sanitarios" and its amendments, is hereby repealed.
Issued at the Presidency of the Republic. San José, on the fourteenth day of November, two thousand fourteen.
Date of generation: 6/5/2026 04:59:40
en la totalidad del texto - Usted está en la última versión de la norma - Texto Completo Norma 38928 Reglamento sobre Rellenos Sanitarios Texto Completo acta: 16A7E8 Nº 38928-S (Este decreto ejecutivo fue derogado por el artículo 46 del Reglamento de parques ambientales para la separación, tratamiento, aprovechamiento y disposición final de residuos sólidos, aprobado mediante decreto ejecutivo N° 44421 del 4 de marzo del 2024) El PRESIDENTE DE LA REPÚBLICA Y LA MINISTRA DE SALUD, En uso de las facultades que confieren los artículos 50 y 140, incisos 3) y 18) de la Constitución Política; artículo 28), párrafo 2, inciso b) de la Ley Nº 6227 del 02 de mayo de 1978 "Ley General de la Administración Pública", artículos 4 y 5 de la Ley Nº 8220 del 4 de marzo del 2002 "Ley de Protección al Ciudadano del Exceso de Requisitos y Trámites Administrativos", su reforma y reglamento y los artículos 4, 7 y 45 de la Ley Nº 8839 del 24 de junio del 2010 "Ley para la Gestión Integral de Residuos".
El siguiente, REGLAMENTO SOBRE RELLENOS SANITARIOS
Considerando:
Por tanto,
DECRETAN
CAPÍTULO I
Disposiciones generales
Además, los requerimientos y condiciones para obras de cierre de vertedero y la reconversión a relleno sanitario. Lo anterior, con la finalidad de proteger la salud pública y el ambiente.
Trámites y requisitos para rellenos sanitarios mecanizados y manuales
CAPITULO II
En caso de ampliación del relleno sanitario más allá de la finca aprobada en el permiso de ubicación, deberá tramitarse de nuevo el respectivo permiso de ubicación y el trámite de revisión de planos.
En casos justificados, el plazo podrá ser ampliado previa notificación al interesado, pero dicha prórroga no podrá exceder los 15 días naturales. Una vez otorgado el permiso tendrá una vigencia de 2 años, plazo que será computado a partir de la fecha de su emisión.
Junto con los planos constructivos deben de adjuntarse la memoria de diseño y el manual de operación y mantenimiento.
a. Los planos constructivos deben de contener lo siguiente:
1. Levantamiento topográfico inicial y final.
2. Delimitación de retiros y servidumbres de cualquier tipo.
3. Vías de acceso, calles internas, cerca perimetral, con sus detalles constructivos.
4. Ubicación de las celdas de disposición de los residuos que incluya los siguientes detalles constructivos:
4.1 Cortes transversales y longitudinales.
4.2 Espesores de residuos y cobertura.
4.3 Recubrimientos de fondo.
4.4 Taludes con el porcentaje de inclinación.
4.5 Espesor de cobertura final.
5. Ubicación de zona de almacenamiento del material de cobertura.
6. Sistema de recolección, conducción y tratamiento de lixiviados, incluyendo reuso y recirculación en caso de utilizarse, con sus detalles constructivos. El sistema de tratamiento de lixiviado debe de cumplir con los requerimientos del Decreto Ejecutivo Nº 31545-S-MINAE "Reglamento Para La Aprobación y Operación De Sistemas de Tratamiento De Aguas Residuales", publicado en el Diario Oficial "La Gaceta" el día 22 de diciembre de 2003.
7. Sistema de recolección, conducción y tratamiento de gases, con sus detalles constructivos.
8. Sistema de recolección periférica e interna, conducción y disposición de las aguas pluviales, con sus detalles constructivos.
9. Detalle de ubicación en planta del terreno de las líneas equipotenciales y las líneas de flujo de las aguas subterráneas; en referencia a la ubicación y detalle constructivo de los pozos de monitoreo de aguas subterráneas.
10. Sistema de distribución de agua potable y eléctrico de todo el proyecto.
11. Edificaciones: oficinas, bodegas, talleres, estación de pesaje, comedores, servicios sanitarios, duchas, vestidores, casetas de vigilancia, área de lavado de camiones recolectores y equipo operativo con todos sus detalles constructivos.
12. Configuración y diseño final del relleno sanitario.
b. La memoria de diseño de un relleno sanitario debe contener lo siguiente:
1. Estimación de la población de diseño.
2. Estimación de la generación de residuos.
3. Estimación de la capacidad volumétrica.
4. Estimación de la vida útil del relleno.
5. Estimación de la producción de gas y diseño del sistema de recolección, tratamiento o aprovechamiento.
6. Estimación de la producción de lixiviados, y diseño de sistema de recolección y tratamiento.
7. Estimación de la cantidad de material de cobertura necesaria, y su disponibilidad en la finca u otras fuentes.
8. Diseño de las dimensiones de las celdas, incluyendo sus taludes.
9. Estimación del volumen de agua pluvial, y diseño del sistema de recolección conducción y disposición.
c. El manual de operación y mantenimiento de un relleno sanitario debe contener lo siguiente:
1. Descripción de la jornada de operación diaria que incluya horarios de trabajo y días de la semana que se labora.
2. Caracterización del perfil del personal necesario para llevar a cabo las diferentes actividades y procedimientos descritos en el manual 3. Programa de avance con respecto a su vida útil.
4. Descripción del equipo y herramientas necesarias para operación del relleno.
5. Descripción detallada de la operación para la disposición de los residuos y su cobertura, tanto durante la estación seca como de la lluviosa.
6. Medidas de mitigación y de control de olores.
7. Medidas de control de aves y vectores.
8. Medidas de mitigación de emisión de material particulado.
9. Enumeración de las dificultades más comunes, acompañada cada una con la solución respectiva.
10. Plan anual de las actividades para el mantenimiento de todo el proyecto incluyendo las rutas internas del relleno sanitario.
Ubicación del Relleno Sanitario
CAPITULO III
En caso de que no se puede determinar el cono de abatimiento la distancia al pozo será de 500 metros.
Especificaciones técnicas
CAPITULO IV
Asimismo, deben encontrarse libres de perforaciones, imperfecciones en la superficie, poseer características que no permitan el paso de los lixiviados, y sus uniones no deben de permitir el paso de líquidos. Sobre la base impermeabilizada con la geomembrana, se colocara una geored de polietileno de alta densidad con geotextil incorporado para facilitar el drenaje de los lixiviados hacia las tuberías de recolección.
a. Poder aislar los residuos del medio circundante, controlar la proliferación de vectores sanitarios, las emanaciones de biogás y los olores molestos, los riesgos de incendio y el ingreso de aguas de lluvias en su interior.
b. Incombustibles.
c. Resistentes a la erosión y el arrastre del viento.
d. No contener sustancias o materiales peligrosos ni ser capaces de liberar contaminantes al medio.
e. Resistente a la escorrentía superficial.
Además, todo relleno sanitario mecanizado debe contar con las siguientes instalaciones: oficinas, bodegas, talleres, estación de pesaje, comedores, servicios sanitarios, duchas, vestidores, casetas de vigilancia, área de lavado de camiones recolectores y equipo operativo.
Los rellenos sanitarios manuales deberán contar con las siguientes instalaciones: bodegas, estación de pesaje, servicios sanitarios, duchas, vestidores, casetas de vigilancia.
Operación y Mantenimiento
CAPITULO V
Dicha maquinaria de reemplazo, debe estar disponible para su funcionamiento en un plazo no superior a 24 horas.
Cuando sea necesario establecer una continuidad vertical entre celdas, esto podrá llevarse a cabo mediante la construcción en forma conjunta con la celda de ductos de drenaje.
Asimismo, dentro de las 24 horas siguientes de ocurrido el evento, deberá remitirse para conocimiento e información de la Dirección de Área Rectora de Salud correspondiente un informe que debe contener lo siguiente:
Si por causa de una contingencia o por cualquier otro motivo resulta imposible o riesgosa la utilización de un área o sector de un relleno sanitario, ésta no podrá ser utilizada sino hasta que el administrador del relleno sanitario presente a la Dirección de Área Rectora de Salud un proyecto que indique las medidas correctivas y de reparación que se requiere implementar para su rehabilitación, elaborado por un profesional en el campo de la ingeniería civil o sanitario. La Dirección de Área Rectora de Salud debe verificar la implementación de las acciones propuestas.
Mantenimiento posterior a la vida útil
CAPITULO VI
El manual debe contener los siguientes aspectos:
En caso de existir un desplazamiento o asentamiento que implique un riesgo potencial, deberán implementarse las medidas correctivas correspondientes.
Vigilancia Estatal
CAPITULO VII
Los parámetros para los pozos de monitoreo y del cuerpo receptor serán los señalados en el articulo 38 inciso d) de este reglamento. muestreos del cuerpo receptor deben realizarse en un sitio aguas arriba y la otra agua abajo del relleno sanitario, a una distancia de por lo menos 25 m del lindero del relleno sanitario y medido en el cauce del río.
Los reportes operacionales incluirán la siguiente información a excepción de las obras de cierre de vertederos que únicamente incluirá los incisos c), d) y e) de este artículo:
a. Promedio diario y mensual de ingreso de residuos por tipo en toneladas.
b. Bitácora de recepción de vehículos, con la siguiente información:
i. Mes correspondiente.
ii. Origen de los residuos: Municipal, gestor, generador iii. Identificación de origen de los residuos: se indica el código del registro del gestor, el municipio o el nombre del generador iv. Peso (en toneladas) v. Tipo de residuos (ordinarios, peligrosos, manejo especial) c. Avance del relleno o de las obras de cierre d. Vida útil actualizada.
e. Análisis de laboratorio, practicados trimestralmente para rellenos mecanizados y obras de cierre del vertedero y semestralmente para los rellenos manuales, de los pozos de monitoreo y del cuerpo receptor del efluente del sistema de tratamiento de lixiviados.
Este análisis incluirá los siguientes parámetros:
1. Demanda Química de Oxígeno (DQO) 2. Potencial Hidrógeno (pH) 3. Sólidos Totales (ST) 4. Cromo Total (Cr) 5. Plomo (Pb) 6. Mercurio (Hg) 7. Níquel (Ni) 8. Conductividad Eléctrica.
9. Cadrnio. (Cd) 10. Cloruros.
11.Nitrato (NO3) 12. Nitritos (NO2) 13. Carbono Orgánico Total.
Los resultados de los análisis del muestreo deben compararse con los valores obtenidos de la línea base al inicio de la operación del relleno sanitario indicado en el artículo 37 de este reglamento.
f. Reporte de cualquier incidente que haya ocurrido durante la operación del relleno y las acciones correctivas correspondientes.
(Así reformado por el artículo 60 del Reglamento para el trámite digital de registros y autorizaciones del Ministerio de Salud en la gestión de residuos en la plataforma SINIGIR, aprobado mediante decreto ejecutivo N° 41525 del 4 de diciembre del 2018)
Obras de cierre de vertederos y reconversión a relleno sanitario
CAPITULO VIII
El sistema de tratamiento de lixiviado debe de cumplir con lo señalado en el Reglamento de aprobación y operación de sistemas de tratamiento de aguas residuales.
Además de una memoria de diseño que contenga lo siguiente:
Y un manual de operación y mantenimiento que contenga:
Además deberá de cumplir con los requisitos técnicos estipulados en el artículo No 20 de este reglamento a excepción de los incisos a, b, c, k y m,
Prohibiciones
CAPITULO IX
El incumplimiento de esta disposición, traerá como consecuencia para el operador del Relleno Sanitario la extensión de una orden sanitaria al administrador del Relleno para que proceda al desalojo de las personas del inmueble, caso contrario, se procesa con la suspensión del Permiso Sanitario de Funcionamiento del establecimiento.
Transcurrido dicho periodo, en caso que se pretenda realizar cualquier tipo de edificación deberán realizarse los estudios geotécnicos para verificar la estabilidad del terreno y además deberá demostrarse la inexistencia de gases y de lixiviados. En caso de incumplirse con lo dispuesto en este artículo, el Ministerio de Salud procederá a girar orden sanitaria solicitando la demolición de la edificación de conformidad con lo anotado en los artículos 355 y 356 de la Ley General de Salud.
Asimismo, la disposición final de residuos de cualquier índole en áreas de protección, humedales, reservas naturales o forestales y similares, áreas de recreación y parques, ríos, quebradas, canales, y en general cualquier cuerpo de agua.
Se prohíbe la quema de residuos o de cualquier otro tipo de material dentro del relleno sanitario. De incurrirse en estas prácticas, el infractor se verá expuesto a la sanción establecida en el artículo 49 de la Ley Nº 8839 del 13 de julio de 2010 "Ley Para La Gestión Integral De Residuos.
DEROGATORIA
CAPITULO X
27378- S del 9 de octubre de 1998, publicado en La Gaceta No. 206 de 23 de octubre de 1998 "Reglamento sobre Rellenos Sanitarios" y sus reformas
Dado en la Presidencia de la República. San José, a los catorce días del mes de noviembre de dos mil catorce
Document not found. Documento no encontrado.